Your site cabins are quietly eating away at your profit.

A heater and an air conditioner fighting each other in the same office. A drying room running all night for one wet coat. Sixty-four hours heating an empty compound, every weekend. None of it is anybody’s fault, and none of it is anybody’s job. That’s what AutoMate is for.

Check how your site compares

or put DataMate on one of your sites, free

The Gaia guarantee

At least a 50% saving on the energy waste in the areas we control, or we credit the difference back.

Projects of six months or more. That’s the only condition. The guarantee, and what it costs

89% Morgan Sindall
Swynnerton
20 cabins · grid
3 March to 31 May 2026
65% Select Plant Hire
Wincham HQ
15 cabins · grid
13 May 2025 to 30 April 2026
57% Morgan Sindall
Maendy
7 cabins
7 May 2024 to 31 October 2025

Measured energy savings over whole monitored periods, from each site's own meter data.

Winner, Sustainability Initiative Award, PlantWorx Innovation Awards 2025, judged by a panel from National Highways, Lynch Plant Hire and the CPA.

Measure it · Fix it · Scale it · Check how your site compares

Measure it. Fix it. Scale it.

Measure it

DataMate measures the real site, free. Every circuit in the board, on your own cabins, until consumption settles, ending with the wastage report.

Fix it

AutoMate removes the waste. The same box, switched on, controlling the loads worth controlling. £25 per cabin or bay per week. Discounts available for upfront terms, ask.

Scale it

Roll the proven system across projects, accounts and cabin suppliers, so cabins arrive on site already fitted.

Not sure it applies to your compound? Check how your site compares first. It is a benchmark, not proof of what your site is doing; DataMate measures that. Take a look inside the demo portal if you would rather see the measurement on a real compound before anyone comes near yours.

One box, working constantly, not just when nobody’s there

One box per cabin, fitted at the distribution board. It measures every circuit all the time and controls the heaters, air conditioning, dehumidifiers, water boilers, lights and sockets, continuously, not only when the cabin is empty. Sometimes that means switching something off. More often it means running it later, in a different order, or for a shorter time. And we prove it in your own kWh.

Nobody is managing the energy in a welfare compound

Not because site teams don't care. Because the circuits are invisible, and there is nothing on site that knows whether a room is occupied.

Heaters run all night in empty rooms

The site office is occupied for part of the day and heated for all of it. Nobody is there to switch it off, and a thermostat has no idea whether anyone is in the room.

Heating and air conditioning fight each other

Two independent controls in one cabin, one calling for heat and one for cooling. Both run. Both appear on the bill, and neither shows up as a fault.

Drying rooms run all weekend, empty

A drying room draws more power than the site office next to it. It gets switched on and left. Nobody notices, because nobody can see the circuit.

These are the findings that come back from real boards, repeatedly. They are also why energy waste survives good intentions: none of it is visible from inside the cabin.

How it works, at the board

How the AutoMate unit intercepts and monitors circuits in a welfare cabin distribution board The incoming supply feeds the cabin distribution board. The AutoMate unit takes its own supply from a dedicated 6 amp MCB and contains four 25 amp double-pole contactors, each with a pre-fitted current transformer, CT1 to CT4. Both poles of a contactor control identical appliances in the same cabin and are never split across two rooms. Which circuit sits on which contactor depends on the cabin type. In a standard cabin the climate appliance, the water boiler, the sockets and the lights. In a drying room the heaters, the dehumidifiers, the fans and the sockets. Separately and never switched: critical always-on circuits including Wi-Fi and data comms, showers and life-safety, plus every other circuit in the board, each carrying its own additional CT. So every circuit is monitored even where it is not controlled. Only line conductors are intercepted; neutrals and earths are never switched and remain in the board unchanged. Incoming supply Cabin distribution board SWITCHED · THE AUTOMATE UNIT 4 × 25A double-pole contactors Both poles control identical appliances in the same cabin, never across two rooms. Own supply from a dedicated 6A MCB. CT1 to CT4 Which circuit, on which contactor Standard cabin: Heater or AC · Water boiler · Sockets · Lights Drying room: Heaters · Dehumidifiers · Fans · Sockets MONITORED ONLY · NEVER SWITCHED Critical always-on circuits Wi-Fi · data comms · showers · life-safety · anything you designate CT Every other circuit in the board One additional CT per circuit. CT Every circuit in the board is CT-monitored, including the ones we never switch. Only line conductors are switched. Neutrals and earths are never switched.

One control box per cabin, fitted at the distribution board. Four double-pole 25A contactors intercept the circuits worth switching. Everything else in the board gets a current transformer so it is measured, whether or not we touch it.

Four 25A double-pole contactors
Both poles of a contactor control identical appliances in the same cabin, never split across two rooms, even for the same type of load.
Which loads get switched depends on the cabin
In a standard cabin: the heater or the air conditioning, the water boiler, the sockets, the lights. In a drying room: the heaters, the dehumidifiers, the fans, the sockets. Where a cabin has both a heater and air conditioning they're separate circuits on separate contactors. Circuits routed through a contactor sit on a breaker of 25A or less. The full scheme, both cabin types.
Critical circuits are never switched
Wi-Fi and data comms, showers, life-safety circuits, and anything else you designate as critical are CT-monitored only.
Every circuit is monitored, even where it isn't controlled
CT1 to CT4 sit on the contactors. Additional CTs go on every other circuit in the board. Your project manager sees the whole board, not just the parts we switch.
Only line conductors are intercepted
Neutrals and earths are never switched and stay in the distribution board unchanged. Power runs bus bar → MCB → contactor → load.
Installed by a qualified electrician
Tested to BS 7671, with a New Installation Certificate handed over on completion.
Then the rules do the work
Timers, occupancy, and peak shaving. Not a thermostat, and not somebody remembering.

Your site manager sees every circuit in the portal. Ask AutoMate a question in plain English, or request a change and we'll handle it.

How AutoMate works, circuit by circuit

We supply a box. We don't supply cabins.

You keep your existing cabin supplier, always.

Our preferred route is the one that costs you least effort: we ship our units to your cabin supplier, and they fit them during cabin setup. The cabin then arrives on site already fitted. Nothing to arrange, no install to schedule around your programme.

That's what we call a Gaia Enabled cabin, their cabin, our box in it. Lead time to a supplier is 10 working days from receipt of purchase order.

You don't need your supplier involved to start, though. On your first sites we install free ourselves, and we already ship boxes to a major plant hire firm who fit them at manufacture.

How it works, start to finish · For cabin suppliers

Installation is included

At every stage, and never charged.

  • Your first sites: we install free.
  • More sites: still installed free as you add them.
  • At scale: your cabin supplier fits them at manufacture; we attend to commission.

Always by a qualified electrician, tested to BS 7671, with a New Installation Certificate handed over on completion.

The guarantee, and what it costs

One guarantee, two limbs

We guarantee at least a 50% saving on the energy waste in the areas we control. And if our fees come to more than we've saved you across the project, we credit the difference, so you cannot end a project out of pocket.

Projects of six months or more. That's the only condition.

Assessed across the project and settled once at the end, not month by month. Savings are valued at your own electricity rate, agreed up front, and measured against your site's own benchmark.

Why we settle at the end

Savings peak in spring and autumn, not winter. Summer has little waste available to remove, and in winter the heating is genuinely needed. The same site read 37% across a summer (13 May to 31 July 2025) and 65% across a full year (13 May 2025 to 30 April 2026).

So an early report on a summer start will look thinner than the final position. Judging it month by month would penalise a project for the time of year it began.

We'd rather tell you that now than have you find it in month two.

£25 per cabin or bay per week

Discounts available for upfront terms, ask.

DataMate monitoring is free, same box, monitoring mode, installation included. No commitment, and no second installation if you move to AutoMate: we switch it on. Full pricing and the guarantee in full.

Other ways to start

  1. Recommended first step

    Get DataMate free on your next project

    We monitor your cabins until consumption settles, and you get the wastage review.

    Your cost: coordination, and one engineer at the board.

    Get DataMate free
  2. Check how your site compares

    Answer a few questions about your welfare setup, and see whether it looks higher-risk than comparable monitored sites.

    Your cost: 20 seconds and an email address for the result.

    Check how your site compares
  3. Talk about full AutoMate

    For teams ready to standardise cabins across projects.

    Your cost: a 30-minute call.

    Book an AutoMate call

Measured on live sites

Whole monitored periods, from the customer's own meter data. Every figure below is traceable to a monthly analysis report.

89% Swynnerton

Morgan Sindall
Site
20 cabins · grid · 3 March to 31 May 2026
Energy
30,310 → 3,151 kWh
27,159 kWh avoided
Cost
£6,518 saved at 24p/kWh

Read the Swynnerton case study

65% Wincham HQ

Select Plant Hire
Site
15 cabins · grid · 13 May 2025 to 30 April 2026
Energy
105,141 → 36,129 kWh
69,012 kWh avoided
Cost
£20,704 saved at 30p/kWh

Select run Gaia on their own head office.

Monitoring was not continuous across this span: no data for February 2026, and a wifi outage 2 to 17 July 2025.

Read the Wincham case study

57% Maendy

Morgan Sindall
Site
7 cabins · generator to 10 Sep 2024, grid after · 7 May 2024 to 31 October 2025
Energy
52,129 → 22,636 kWh
29,492 kWh avoided
Cost
£11,669 saved at 25p/kWh

The longest track record in the estate, eighteen months.

The 57% is the whole period, including the diesel saved while the site ran on a generator. The £11,669 is on the grid basis only.

Read the Maendy case study

Electricity rates are supplied by each customer and range from 24p to 30p per kWh, so the rate is printed next to every £ figure. £ savings are not comparable between sites and are never averaged or totalled; compare on kWh and percentage.

Check how your site compares All case studies

The benchmark is open, no email needed to see your result.